| cUL RW90 Aluminum 600V XLPE Building Wire | ||
| Voltage: | 600V | |
| Structure: | Conductor | Stranded AA-8000 Series Aluminum Alloy (ACM) |
| Insulation | Cross-linked Polyethylene (XLPE) | |
| Insulation Colour | Standard colours are available in Black Red Blue White and Green | |
Aluminum RW90 is for open wiring used in raceways (except cabletroughs and ventilated fexible cableways) in dry or wet locations. For open wiring exposed to the weather. Minimum recommended installation temperature minus 40°C (with suitable handling procedures). Maximum conductor temperature 90°C.
600V
-40°C to 90°C
CSA C22.2 No. 38
Stranded AA-8000 Series Aluminum Alloy (ACM)
Cross-linked Polyethylene (XLPE)
Standard colours are available in Black Red Blue White and Green
| Conductor | Insulation Thickness | Nominal O.D. | Approx. Weight | ALLOWABLE AMPACITY (AMPS) 30℃ AMBIENT - OPEN AIR* | ALLOWABLE AMPACITY (AMPS) 30℃ AMBIENT - CABLE IN CONDUIT* | ||||||||
| Size (AWG or kcmil) | # of Strands | inches | mm | inches | mm | lbs/Mft | kg/km | 60℃ | 75℃ | 90℃ | 60℃ | 75℃ | 90℃ |
| 6 | 7 | 0.045 | 1.14 | 0.259 | 6.58 | 37 | 55 | 65 | 75 | 85 | 40 | 50 | 55 |
| 4 | 7 | 0.045 | 1.14 | 0.303 | 7.7 | 55 | 82 | 85 | 100 | 115 | 55 | 65 | 75 |
| 2 | 7 | 0.045 | 1.14 | 0.358 | 9.09 | 82 | 122 | 115 | 135 | 150 | 75 | 90 | 100 |
| 1 | 8 | 0.055 | 1.4 | 0.409 | 10.39 | 104 | 155 | 130 | 155 | 175 | 85 | 100 | 115 |
| 1/0 | 10 | 0.055 | 1.4 | 0.446 | 11.33 | 128 | 190 | 150 | 180 | 205 | 100 | 120 | 135 |
| 2/0 | 12 | 0.055 | 1.4 | 0.486 | 12.34 | 157 | 234 | 175 | 210 | 235 | 115 | 135 | 150 |
| 3/0 | 16 | 0.055 | 1.4 | 0.533 | 13.54 | 193 | 287 | 200 | 240 | 270 | 130 | 155 | 175 |
| 4/0 | 19 | 0.055 | 1.4 | 0.585 | 14.86 | 239 | 356 | 235 | 280 | 315 | 150 | 180 | 205 |
| 250 | 22 | 0.065 | 1.65 | 0.65 | 16.51 | 286 | 426 | 265 | 315 | 355 | 170 | 205 | 230 |
| 300 | 35 | 0.065 | 1.65 | 0.703 | 17.86 | 339 | 504 | 295 | 350 | 395 | 195 | 230 | 260 |
| 350 | 35 | 0.065 | 1.65 | 0.749 | 19.03 | 397 | 582 | 330 | 395 | 445 | 210 | 250 | 280 |
| 400 | 35 | 0.065 | 1.65 | 0.792 | 20.12 | 442 | 658 | 355 | 425 | 480 | 225 | 270 | 305 |
| 500 | 35 | 0.065 | 1.65 | 0.869 | 22.07 | 544 | 809 | 405 | 485 | 545 | 260 | 310 | 350 |
| 600 | 58 | 0.08 | 2.03 | 0.976 | 24.79 | 663 | 987 | 455 | 545 | 615 | 285 | 340 | 385 |
| 750 | 58 | 0.08 | 2.03 | 1.071 | 27.2 | 816 | 1214 | 520 | 620 | 700 | 320 | 385 | 435 |
| 1000 | 58 | 0.08 | 2.03 | 1.223 | 31.06 | 1070 | 1592 | 630 | 750 | 845 | 375 | 445 | 500 |
SOUTH CABLE is a company specializing in the research, development, manufacturing,and sales of high-end wire and cable products.
Always a pre-production sample before mass production; Always final Inspection before shipment.
Wire, Cable
We have CSA and CUL certifications, We have Fifteen years of experience in design and development.
Accepted Delivery Terms: FOB,CFR,CIF,EXW;
Accepted Payment Currency:USD,EUR;
Accepted Payment Type:T/T,L/C,Money Gram,Western Union;Language Spoken:English,Chinese,French
Most quotes are returned within 24 hours
TEST
Tests are divided into routine tests, sampling tests and type test items.
routine tests: Tests carried out by the manufacturer on all manufactured lengths of finished cables toverify that all cables comply with specified requirements.Routine test items :Conductor resistance measurement, voltage test.
Sampling tests: Tests carried out by the manufacturer on specimens of finished cables or on certaincomponents taken from finished cables at specified frequencies to check whether the cables complywith specified requirements.
Sampling test items:Conductor inspection, dimensional inspection,thermal extension testing ofinsulation and elastomer sheaths.
Type test:Tests carried out on normal commercial principles before supply of a type of cable covered by this standard to demonstrate that the cable has satisfactory performance under the conditions of intended use.
Type testing includes electrical type testing and non-electrical type testing items.
Electrical type test items:1) Insulation resistance measurement at ambient temperature.2) Measurement of insulation resistance at maximum conductor temperature during normal operation.3) 4h voltage test.
Non-electrical type test items include insulation non-electrical type test and sheath non-electrical type test.
Insulation non-electrical type test items: Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Thermal shock test、Thermal extension test and water absorption test, etc.
Sheath non-electrical type test items:Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Weight loss test and thermal shock test, etc.