SOUTH CABLE
XHHW-2 Copper Conductor
Voltage:600V
Structure:ConductorClass B stranded bare copper per ASTM B3 and ASTM B8
InsulationCross Linked Polyethylene (XLPE) , Silicone-Free, Abrasion, High-Heat, Moisture Resistant
Insulation ColourBlack, Customized as needed


Overview Specifications FAQ Test&Acceptance Send Message

APPLICATION

XHHW-2 Wire can be used as a building line, widely used in highrise buildings, subways, commercial offices and other large public places, can also be used in photovoltaic power stations, mobile energy storage power stations, wind energy storage systems and other new energy fields.

XHHW

UL 44 XHHW‑2 copper conductor with heat‑moisture resistant XLPE insulation. Rated 600V, 90℃ for wet and dry locations, compliant with NEC. Class‑B stranded copper for conduit and cable‑tray electrical wiring applications.

CHARACTERISTICS

Voltage Rating Uo/U

600V

Temperature Rating

-40°C to 90°C

STANDARDS

ASTM B3, B8

UL 1581 - Flame Exposure Test

UL 44 - Thermoset-Insulated Wires and Cables

National Electrical Code (NEC)

CONSTRUCTION

Conductor

Class B stranded bare copper per ASTM B3 and ASTM B8

Insulation

Cross Linked Polyethylene (XLPE) , Silicone-Free, Abrasion, High-Heat, Moisture Resistant

Insulation Colour

Black, Customized as needed

SIZE (AWG OR KCMIL)STRAND
QTY.
Nominal Insulation ThicknessOUTSIDE DIAMETERAPPROX. NET WEIGHTALLOWABLE AMPACITY1 (AMPS)
MMINMMINKG/MILLBS/1000FT75º C90º C
1470.760.033.330.13125172025
1270.760.033.810.1537252530
1070.760.034.390.17357383540
871.140.0455.990.23694635055
671.140.0456.960.2741501016575
471.140.0458.180.3222281538595
371.140.0458.890.35280188100115
271.140.0459.700.382348234115130
1191.400.05510.600.417451303130145
1/0191.400.05511.500.453557374150170
2/0191.400.05512.600.496690464175195
3/0191.400.05513.800.543859577200225
4/0191.400.05515.100.5941068718230260
250371.650.06516.700.6571229826255290
300371.650.06518.000.7091466985285320
350371.650.06519.200.75617021144310350
400371.650.06520.200.79519371302335380
500371.650.06522.200.87424081618380430
600612.030.0824.900.98029291969420475
750612.030.0827.301.07535882411475535
1000612.030.0831.201.22835882411475535


  • Who we are?

    SOUTH CABLE is a company specializing in the research, development, manufacturing,and sales of high-end wire and cable products.

  • How can we guarantee quality?

    Always a pre-production sample before mass production; Always final Inspection before shipment.

  • What can you buy from us?

    Wire, Cable


  • Why should you buy from us not from other suppliers?

    We have CSA and CUL certifications, We have Fifteen years of experience in design and development.

  • What services can we provide?

    Accepted Delivery Terms: FOB,CFR,CIF,EXW;
    Accepted Payment Currency:USD,EUR;
    Accepted Payment Type:T/T,L/C,Money Gram,Western Union;Language Spoken:English,Chinese,French


  • How long does it take to get a quote back

    Most quotes are returned within 24 hours

TEST

Tests are divided into routine tests, sampling tests and type test items.

1.Routine tests

routine tests: Tests carried out by the manufacturer on all manufactured lengths of finished cables toverify that all cables comply with specified requirements.Routine test items :Conductor resistance measurement, voltage test.

2.Sampling tests

Sampling tests: Tests carried out by the manufacturer on specimens of finished cables or on certaincomponents taken from finished cables at specified frequencies to check whether the cables complywith specified requirements.

Sampling test items:Conductor inspection, dimensional inspection,thermal extension testing ofinsulation and elastomer sheaths.

3.Type test

Type test:Tests carried out on normal commercial principles before supply of a type of cable covered by this standard to demonstrate that the cable has satisfactory performance under the conditions of intended use.

Type testing includes electrical type testing and non-electrical type testing items.

Electrical type test items:1) Insulation resistance measurement at ambient temperature.2) Measurement of insulation resistance at maximum conductor temperature during normal operation.3) 4h voltage test.

Non-electrical type test items include insulation non-electrical type test and sheath non-electrical type test.

Insulation non-electrical type test items: Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Thermal shock test、Thermal extension test and water absorption test, etc.

Sheath non-electrical type test items:Dimensional measurements、mechanical properties(tensile strength and Elongation at break)、High temperature pressure test、Low temperature performance、Weight loss test and thermal shock test, etc.


Name:
E-mail:*
Phone:*
Country:
Message:*